In the pipeline - Information Blog # 61- LEAK DETECTION - Dandenong

February 23 2016

​CASE STUDY 1:

LEAK INVESTIGATION WORKS

Attended property on 09/02/16 to carry out leak investigation works.

FINDINGS/ACTIONS -Accessed property and found water damage on internal wall of bedroom -Found shower to be on the adjoining wall -Carried out digital moisture testing and pressure testing -Found slight increase in moisture during pressure testing -Found a pressure drop of approx. 50-75kpa from the shower breach -Spray tested shower wall - no increase in moisture test -Took notes for recommendation -Packed up and left site clear

RECOMMENDATION 1. Remove tiles to expose shower breach to investigate further for leaks


Webb Plumbing Services: Rapid Reliable Response